The power factor correction (pFC of DC variable frequency air conditioners refers to the power factor correction circuit. It is a circuit used to improve the power factor of air c...

What is the pFC circuit of DC inverter air conditioning?

The power factor correction (pFC) of DC variable frequency air conditioners refers to the power factor correction circuit. It is a circuit used to improve the power factor of air conditioning systems.

< br >

The power factor is the ratio between the useful power and the apparent power in an AC circuit. Apparent power refers to the total power in the circuit, including useful power and reactive power (mainly manifested as the phase difference between current and voltage caused by inductance or capacitance). By using a power factor correction circuit, the power factor can be increased to a value close to 1, thereby reducing reactive power consumption and improving energy utilization efficiency.

< br >

In DC variable frequency air conditioning, the main role of the pFC circuit is to make it closer to 1 by correcting the power factor at the power input. This can reduce harmonic pollution from the power supply, reduce the load on the grid, and improve the energy efficiency of the entire air conditioning system. pFC circuits are usually implemented with electronic components (such as capacitors, inductors, and semiconductor devices), by controlling the phase relationship between current and voltage, so that the power factor is close to 1. This can improve the electrical performance of the air conditioning system on the grid, reduce energy consumption, and achieve energy conservation and environmental protection goals.

< br >

It should be noted that different air conditioning manufacturers and models may use different pFC circuit designs, so the specific circuit structure and implementation may vary. It is recommended that you consult the product manual of the specific air conditioner model you are using or consult with the manufacturer for their specific pFC circuit design.


    The pFC of a DC Inverter Air Conditioner is a Power Factor Correction circuit. Power factor is the degree of influence of electrical equipment on the load of the power grid in the working process, which reflects the effective use of the equipment to the power grid.

< br >

The role of the pFC circuit is to improve the power factor of the air conditioning system, thereby reducing the pollution and load on the grid. When the DC variable frequency air conditioner is started, it will draw electrical energy from the grid, and carry out power factor correction through the pFC circuit, the current waveform becomes closer to the sine wave, and the phase difference between the current and voltage is as close to zero as possible. This can reduce the harmonic interference of air conditioning on the power grid and the loss caused by low power factor, improve the efficiency and stability of the system.

< br >

pFC circuit usually adopts the filter network composed of inductors and capacitors, and realizes power factor correction by controlling the charging and discharging process of capacitors. This can make the air conditioning system more efficient and stable when working, and meet the power factor requirements of the power grid. By increasing the power factor, pFC circuits can reduce energy consumption, reduce energy waste, and have a positive effect on energy conservation and environmental protection.