Set the input AC voltage (RMS) to E, the connected load to RL, and the output voltage to UL(DC)
Due to the capacitor filter, its charge and discharge effect, the DC voltage is increased after filtering.
When RL is open,UL=√2E, when RL is large,UL is close to √2E,
When connected to a normal load,UL≈1.2E