Remove the machine as follows
1 screwdriver, wrench, hammer to remove the air conditioning, first of all to receive fluorine, boot refrigeration, compressor work after the close of the high pressure valve operation, close the low pressure valve, stop.
2. Unplug the power plug in winter, you can unplug the wiring of the four-way valve of the external machine! Remove the outdoor unit copper pipe connector, and remove the outdoor unit cable connector.
3. Unscrew the lock female of the indoor unit connection using a wrench, and screw the silk lines of the connectors of the indoor unit with the prepared sealing sodium to prevent the silk lines of the connectors from being damaged during transportation.
4. Use the cross to remove the control line. At the same time, it should be marked to avoid incorrect connection during installation. If the signal line or power line is connected incorrectly, it will cause the external machine to not operate, or the machine is not controlled.
5. The inner machine hanging plate is generally fixed firmly, and it is difficult to unload; After unloading, remove the hanging plate, place it on the flat cement floor, gently pat it flat and correct it.