The current instability of adjustable DC power supply may be caused by many reasons. Here are some suggestions to help you diagnose and resolve the problem:1. Check the load: First...

What is the current instability of adjustable DC regulated power supply?

The current instability of adjustable DC power supply may be caused by many reasons. Here are some suggestions to help you diagnose and resolve the problem:

< br >

1. Check the load: First, check the load device connected to the power supply. Ensure that the load equipment is working properly and that its current requirements are within the rated range of the power supply. If there is a problem with the load device, it may cause the power current to be unstable.

< br >

2. Check the power input: Ensure that the power input is stable and does not fluctuate. Unstable power input may cause unstable current output. Check input power cables, plugs, and sockets to make sure they are in good contact and not loose.

< br >

3. Check connections and connectors: Check the connections and connectors of the power output to ensure that they are in good contact and are not loose. Loose joints may result in unstable current output.

< br >

4. Check heat dissipation: An overheated power supply may cause unstable current output. Check the heat dissipation fans and fins of the power supply to ensure that they work properly and are free of dust accumulation. If the heat dissipation is poor, clean the dust and ensure that the fan rotates properly.

< br >

5. Check the power circuit: If the above methods can not solve the problem, the power circuit may be faulty. This may require inspection and repair by professional technicians. Contact a professional electrician or equipment manufacturer for assistance.

< br >

Before performing any inspection or repair, be sure to follow safe operating procedures. If you are not familiar with the handling of electrical equipment, be sure to seek the help of a professional electrician. Be sure to follow safe operating procedures before performing any repairs.


It may be due to the following reasons:

1. The internal components of the regulator are aging or damaged, resulting in changes in current;

2. External load changes cause current fluctuations, such as load changes, load short circuits, line failures, etc.;

3. The input voltage fluctuates, resulting in unstable output current;

4. The working environment temperature is too high or too low, resulting in changes in component parameters and affecting the current stability. For different reasons, corresponding repair or adjustment measures can be taken to ensure the stability of the current.


Your question doesn't make it clear whether the current is unstable under constant load or something. Dc regulated power supply is voltage stable, current changes with the load, such as the load is a sound equipment, then the greater the volume, the greater the current, so current instability is normal.