1, if the socket is plugged in a trip problem, there may be a leakage situation. Because the installed socket is unreasonable, such as the neutral line and the ground line are reversed, as long as it is plugged in, there will be a problem of leakage tripping.
2, there may also be an overload problem in the circuit, if the selected circuit breaker is 10, but the electrical power above the circuit has exceeded 2.2 kilowatts, once plugged in, there will be an overload trip problem.
3, another reason is that there is a short circuit in the circuit, which will directly lead to tripping. We need to check which part of the circuit is short-circuited and needs to be repaired. If the wire connected to the socket is relatively thin, there will be an immediate tripping problem, once the plugged electrical power is relatively large, it will accelerate the aging of the wire, and then there will be overheating phenomenon, burn the wire, and seriously cause a fire.
If the socket wire connection is not in place, we need to remove the socket, rearrange the wire, pay attention to the zero wire and ground wire can not be connected wrong.
In order to avoid overload tripping, the selected socket power must meet the requirements, the rated power of the circuit breaker is best to choose more than 1.5 times, so as to meet the standard
If there is a problem in the circuit, the wire needs to be rearranged, and the wire should be selected to match the size of the wire. If you choose a 1 square wire, it can carry 1.8 kilowatts of electrical appliances. If it is a 4 square wire, generally speaking, it can bring about 7 kilowatts of electrical appliances. The 6 square wire can carry 8.5 kilowatts of electrical appliances, so be sure to strictly comply with its load to connect.
1. First eliminate the cause of electrical leakage, because electrical leakage just plug in will trip!
< br >
2. Plug in other electrical appliances, and also trip for a period of time, and plug in other sockets do not jump, this is the reason for the socket or socket box connector, replace it.
< br >
3. If the other plug in electrical appliances also trip, that is the reason above the line.
< br >
4. The family small distribution box socket output pressure screw, completely loosen the line, and then all the closing, to be opened for a period of time, if the jump is a small brake problem, if not jump is a line jump problem.
It may be that the socket is wired incorrectly, which may cause tripping when used. This is generally the case for newly installed sockets, such as the neutral line and the ground line are reversed. If the upper circuit breaker is a leakage protector, it will be judged as a leakage trip when used.
There is a short circuit or leakage fault inside the electrical appliance, and it will trip when plugged in the socket. Leakage protector to overload, short circuit, leakage protection function. If the electrical equipment used has a short circuit or leakage fault, it will cause the circuit breaker to trip when used.